Wind Resistance – Mast Wind Resistance and Calculation Method | |||||||||||||||||||||||||||||||||||||||||||||||||||
1) Knowledge of Mast Wind Resistance Mast wind resistance is one of the important technical indicators of mast products. Every customer wants to know how much wind force that their mast can withstand after installing loads; however, hardly anyone can answer this question accurately.This is because mast’s wind resistance performance is determined by the following three factors: A Mast structure and material B Use height of mast C Weight, volume and shape of loads In case that the above three conditions are provided, we can use the following three methods to calculate specific wind resistance index: (1) Theoretical calculation: Use finite element analysis and other methods. (2)Simulation experiment: Convert different scales of wind power into wind pressure, and then use physical method (tensiometer) for testing. (3) Wind tunnel experiment: Place the mast and loads in the wind tunnel, and simulate wind speed for testing. In the above three methods, the third method can provide a more realistic value. However, the cost and condition requirements for wind tunnel experiment are very high. For example, is there a big enough wind tunnel for experiment of an 18-meter-high mast with loads? Is the experiment possible ? How much will it cost? These are all problems. Therefore, for mast manufacturers, wind resistance index of mast can only be provided using the first two methods
2)Calculation Method of Mast Wind Resistance |
|||||||||||||||||||||||||||||||||||||||||||||||||||
1.1、Designed benchmark wind speed of lifting rod ▽=100km/h≈28m/s 1.2、When ▽= 28m/s, estimate wind resistance D borne by the lifting rod. 1.3、The lifting rod has a total of 4 segments. Specific size is shown in the table. |
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
2.Wind Resistance Calculation |
|||||||||||||||||||||||||||||||||||||||||||||||||||
w=πd²/32 ﹛1-﹙do/d ﹚4﹜=3.14×202²/32 ﹛1-﹙190/202 ﹚4﹜=181332mm² |
|||||||||||||||||||||||||||||||||||||||||||||||||||
2.2 Gust wind coefficient
The so-called gust Kg is the ratio of maximum instantaneous wind speed V2 and mean wind speed V2 within observation time. It is related to observation time, average wind speed, topography, surface roughness, recurrence interval of benchmark wind speed, and other factors. Generally, Kg is between 1.2 and 1.5, here Kg=1.3.
2.3 Reynolds Number of Lifting Rod in Different Diameter Segments
It can be seen from the curve that the Re range of the lifting rod is just within the area of CD=1.2. =1.2×2/20×36.4²×0.202×1.7×1.3² =57.67kg
2.5 Strength Check
6063-T6下σ=205Mpa,To ensure safety, takeσ=160Mpa
|
Related Items
-
Posicionador de Antena e Luzes
Luzes giratórias da busca do diodo emissor de luz -
Mastro Multi-Parafuso
Mastro mecânico motorizado ultra pesado -
Torre de luz LED móvel
Torre de luz LED móvel -
Mastro telescópico de 4,5 m -
Electro Mast
Electro mastro mecânico -
Solar Light Tower
Energia solar móvel levou torre de luz -
TH-60-4600
ARFF seis 8metros luz robótico torre -
THH-2521000
Sistema de iluminação móvel veículo -
Locking Mast
mastro de antena -
Manual Winch Mast
Manual de seis 5.8metros guincho mastro mecânico -
Locking Mast
Mastros de antenas -
TH-NDC-01
Militar Dome câmera de vigilância do Sistema de mastro -
TRIPÉ DE TODOS OS TERRENOS
Suporte de Tripé para Todo Terreno -
PAN DE INCLINAÇÃO DE SERVIÇO PESADO
Resistente a prova de explosão pan tilt -
Torre telescópica elétrica -
Mastro motorizado de 8 metros